0 pcs of choose AddA cable that connects a pulse massager to the electrodes that touch the body. The tips come in several shapes, so pick the one that matches the unit and the accessories you already use.
- Several tip shapes
- International standard jack
- Replace the cable alone
- Cheapest consumable part
- Plain packaging
- Plain-package delivery with cash payment on arrival
- Delivery to Nha Trang, Da Nang, Ho Chi Minh City, Hanoi, Bac Ninh and Phu Quoc
- Product guide
- Plain unmarked packaging
- Korean-run support
- Cash on delivery
Message us on Telegram for help choosing products or placing an order.
Telegram supportProduct details
Review the features and intended use to decide whether this product suits you.
A cable that connects a pulse massager to the electrodes that touch the body. The unit itself often stays fine while only the cable fails, and because most shops sell them as a set, one broken cable means buying the whole device again. The supplier states that it sells this cable on its own.
The tips come in several shapes
There are two rounded tips, two straight pins, one rounded and one straight paired together, four straight pins, four rounded tips and other layouts. Which shape fits depends on the accessory that touches the body. The photos also show a cable that splits into four branches and a cable that attaches with snap fasteners.
It only plugs in if the standard matches
The supplier explains that these cables are built to an international standard and fit most of the pulse massagers on the market. The jack on the device end is bent at a right angle, so the cable is pressed less when you sit down with it attached. When you order, check both the socket on your unit and the contact shape on your accessories.
Before you use it
The warning the supplier gives the most weight to is about sequence. If you switch the unit on before both poles are touching the body, a strong current hits you all at once. Attach first and then switch on, switch off and then detach. A cable with split insulation is dangerous to keep using and has to be replaced, and water reaching it during use will short it out. On the electrode end, though, a dry surface concentrates the current on a few points and stings, so it is better to leave a thin film of water or water-based gel on the skin.
Key points
Specifications
Check the product category and included parts before purchase.
| Product name | Replacement lead wire for e-stim unit (multiple tip types) |
|---|---|
| Category | E-stim |
| Intended for | Adults only |
Use and safety
Follow the use and care steps for comfortable, hygienic use.
How to use
- STEP
Look the cable over first for any spot where the insulation has worn through.
- STEP
Place the electrodes on the body first, then clip the cable to them.
- STEP
Turn the unit on only after both contacts are on the body.
- STEP
Start the intensity at the lowest setting and raise it from there.
- STEP
When you finish, switch the power off first and then unplug the cable.
Cleaning and storage
Keep it away from water and wipe it with a dry cloth after use. The point where the jack comes out is where it breaks first, so do not bend it sharply when you coil it, and wind it in a wide loop. Debris on the contact metal weakens the connection, so rub it clean with a dry cloth. If the insulation splits and you can see copper wire, replace the cable rather than repairing it.
Caution
This is an accessory for a device intended for adults only. The supplier states plainly that you must not turn the unit on before both poles are touching the body, because switching on with only one side attached sends a strong current through you. Do not use a cable whose insulation has worn through to the copper, and keep it away from water while in use. Place both contacts on the same side below the waist so the current does not cross your chest and pass through your heart, never place them on the head or neck, and do not use it if you have a pacemaker, a heart condition or epilepsy, or if you are pregnant. Never attach or remove electrodes while the power is on.
Product reviews 0
Loading reviews.
Photo reviews 0
No reviews match the selected filters.
There are no reviews yet
Leave a review, then message us on Telegram to receive 5% off your next order.
Leave a review, then message us on Telegram to receive 5% off your next order.
Reviews appear on the product page as soon as they are submitted. We may remove offensive or promotional content without notice.
Delivery and returns
What you need to know from ordering through delivery and return questions.
| Packaging | We dispatch every order in plain packaging with no product name on the outside. |
|---|---|
| Dispatch timing | Shipping is free everywhere. Prepare the final amount in Vietnamese dong and pay the courier in cash when the plain package arrives. |
| Delivery region | After you order, we will confirm the available delivery option and timing for Nha Trang, Da Nang, Ho Chi Minh City, Hanoi, Bac Ninh, Phu Quoc and other locations in Vietnam. |
| Exchanges and returns | For hygiene and safety, opened or used items cannot be exchanged or returned. |
| Damage or incorrect items | If your order arrives damaged or incorrect, message us on Telegram as soon as possible and we will arrange an exchange. |
Product questions
Answers to common questions before ordering.
How is the order packaged?
How do I pay?
How long does delivery take?
Where can I ask a question?
Can I return an item?
Need help choosing a product or arranging delivery? Message our Korean-run team on Telegram.
Telegram support